Specications (continued)
Altivar
®
12
variable speed drives
Drive specications
Output frequency range Hz 0.5 to 400
Congurable switching frequency kHz Nominal switching frequency: 4 kHz without de-rating in continuous operation
Adjustableduringoperationfrom2to16kHz
Above 4 kHz in continuous operation, apply de-rating to the nominal drive current of:
10% for 8 kHz
20% for 12 kHz
30% for 16 kHz
Above 4 kHz, the drive will reduce the switching frequency automatically in the event
of excessive temperature rise.
See the de-rating curves in the User Manual, available on our website at
"www.schneider-electric.us".
Speed range 1 to 20
Transient overtorque 150 to 170% of the nominal torque depending on the drive rating and the type of motor
Braking torque Up to 70% of the nominal torque without resistor
Up to 150% of the nominal motor torque with braking unit (optional) at high inertia
Maximum transient current 150% of the nominal drive current for 60 seconds
Motor control proles Standardprole(voltage/frequencyratio)
Performanceprole(sensorlessuxvectorcontrol)
Pump/fanprole(Kn
2
quadratic ratio)
Electrical power specications
Power supply Voltage V 100 - 15% to 120 + 10% single-phase for ATV12ppppF1
200 - 15% to 240 + 10% single-phase for ATV12ppppM2
200 - 15% to 240 + 10% three-phase for ATV12ppppM3
Frequency Hz 50 to 60 ± 5%
Isc (short-circuit current) A y 1000 (Isc at the connection point) for single-phase power supply
y 5000 (Isc at the connection point) for three-phase power supply
Drive supply and output voltages Drive supply voltage Drive output voltage for motor
ATV12ppppF1 V 100 to 120 single-phase 200 to 240 three-phase
ATV12ppppM2 V 200 to 240 single-phase
ATV12ppppM3 V 200 to 240 three-phase
Maximum length of motor
cable (including tap links)
Shielded cable m 50
Unshielded cable m 100
Drive noise level ATV12H018F1, H037F1
ATV12H018M2 to H075M2
ATV12H018M3 to H075M3
ATV12Pppppp
dBA 0
ATV12H075F1
ATV12HU15M2, HU22M2
dBA 45
ATV12HU15M3 to HU40M3 dBA 50
Electrical isolation Electrical isolation between power and control (inputs, outputs, power supplies)
Connection specications
(drive terminals for the line supply, the motor output and the braking unit)
Drive terminals R/L1, S/L2/N, T/L3, U/T1, V/T2, W/T3, PA/+, PC/–
Maximum wire size and
tightening torque
ATV12H018F1, H037F1
ATV12H018M2 to H075M2
ATV12H018M3 to H075M3
ATV12P037F1
ATV12P037M2 to P075M2
ATV12P037M3, P075M3
3.5 mm
2
(12 AWG)
0.8 Nm
ATV12H075F1
ATV12HU15M2, HU22M2
ATV12HU15M3 to HU40M3
ATV12PU15M3 to PU40M3
5.5 mm
2
(10 AWG)
1.2 Nm
Introduction:
page 8
References:
page 14
Dimensions:
page 18
Connections:
page 22
Functions:
page 26
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Kommentare zu diesen Handbüchern