PROCEDURE 2: CHECKING SUPPLY VOLTAGE
Measure the input line voltage to determine if the voltage is within the
drive controller tolerance.
1. Perform the Bus Voltage Measurement procedure on page 87.
2. Attach meter leads to L1 and L2. Set the voltmeter to the 600 Vac
scale.
3. Reapply power and check for the correct line voltage, shown on the
drive controller nameplate rating.
4. Remove power and repeat the procedure for L2 and L3, and L1 and
L3.
5. When all phases have been measured, remove power. Remove leads
and replace all covers.
+
–