ALTIVAR
58 Keypad Display VVDED397047US R8/01
Chapter 1 — Overview 08/01
12
© 1998–2001 Schneider Electric All Rights Reserved
The keypad display can be mounted and removed while there is power to
the drive controller. If the keypad display is removed while command of
the drive controller from the keypad display is active, the drive controller
will trip on the serial link fault. See SLF in Table 25 beginning on
page 91.
Remote Mounting
To remotely mount the keypad display, use the keypad display remote
mounting kit, part number VW3A58103. This kit has an IP65 rating. This
kit contains a three meter (9.8 ft.) cable with connectors, parts for
mounting the keypad display on the cover of an enclosure, and an
instruction sheet.
Setting the 50/60 Hz Switch
DANGER
HAZARDOUS VOLTAGE
• Read and understand this bulletin in its entirety before installing
or operating ALTIVAR 58 drive controllers. Installation,
adjustment, repair, and maintenance of these drive controllers
must be performed by qualified personnel.
• Disconnect all power before servicing the drive controller. WAIT
THREE MINUTES until the DC bus capacitors discharge, then
measure DC bus capacitor voltage between J2-4 (+) and J2-5 (-)
for drive controllers ATV58U09M2 and U18M2, or between J2-5
(PA) and J18-7 for drive controllers ATV58U29M2 to U72M2 and
ATV58U18N4 to D79N4, to verify that the DC voltage is less than
45 V. Refer to the Bus Voltage Measurement Procedure page 87.
• DO NOT short across DC bus capacitors or touch unshielded
components or terminal strip screw connections with voltage
present.
• User is responsible for conforming to all applicable code
requirements with respect to grounding all equipment.
• Many parts in this drive controller, including printed wiring boards,
operate at line voltage. DO NOT TOUCH. Use only electrically
insulated tools.
Electrical shock will result in death or serious injury.