Inhaltsverzeichnis

Seite 1 - Software Quick Start Guide

31002962 00Advantys STB Configuration Software Quick Start Guide890USE18000 Version 1.031002962 00

Seite 2

Requirements10890USE18000 September 2003System RequirementsHardware RequirementsYour PC needs to meet the following hardware requirements to run the A

Seite 3 - Table of Contents

Requirements890USE18000 September 2003 11Installing and Uninstalling the SoftwareBefore You Start Before you install the Advantys configuration softwa

Seite 4 - 4 890USE18000 September 2003

Requirements12890USE18000 September 2003

Seite 5 - Safety Information

890USE18000 September 2003 132Screen ElementsIntroductionOverview The concepts of an island and a workspace are explained, and the elements that appea

Seite 6

Elements14890USE18000 September 2003What Is an Island?Overview Before we describe the different capabilities available in the Advantys configuration s

Seite 7 - About the Book

Elements890USE18000 September 2003 15A Logical Island The Advantys configuration software lets you model a physical island so that it can be tested ag

Seite 8

Elements16890USE18000 September 2003Creating a Project with the Advantys Configuration SoftwareOverview The Advantys configuration software provides a

Seite 9 - Requirements

Elements890USE18000 September 2003 17Project Work FlowThe following flowchart describes the work flow associated with a valid island configuration: fr

Seite 10 - System Requirements

Elements18890USE18000 September 2003The WorkspaceOverview The workspace is a project environment in the Advantys configuration software. The workspace

Seite 11 - 890USE18000 September 2003 11

Elements890USE18000 September 2003 19A Workspace ScreenA workspace screen consists of the following areas: 1 toolbars2 workspace browser3 island ed

Seite 12

2890USE18000 September 2003

Seite 13 - Screen Elements

Elements20890USE18000 September 2003Workspace ToolbarsOverview The Advantys configuration software has four groups of toolbars available on the worksp

Seite 14 - What Is an Island?

Elements890USE18000 September 2003 21The Standard ToolbarThe standard toolbar has11 buttons. The commands associated with these buttons are Windows-st

Seite 15 - Elements

Elements22890USE18000 September 2003The Edit Toolbar The edit toolbar has seven buttons. The commands associated with these buttons let you edit objec

Seite 16

Elements890USE18000 September 2003 23The Island ToolbarThe island toolbar has nine buttons. The commands associated with these buttons support island-

Seite 17 - Project Work

Elements24890USE18000 September 2003Workspace BrowserOverview The workspace browser is an hierarchical view of all of the island (.isl) files in the a

Seite 18 - The Workspace

Elements890USE18000 September 2003 25Shortcut Menus When you right-click on a node in the workspace browser, a shortcut menu with a list of commands a

Seite 19 - 890USE18000 September 2003 19

Elements26890USE18000 September 2003Island EditorOverview The island editor provides a graphical display of the logical islands (the .isl files) in th

Seite 20 - Workspace Toolbars

Elements890USE18000 September 2003 27Components of the Island EditorThe island editor consists of a graphical image of an island and a set of tabs bel

Seite 21 - The Standard

Elements28890USE18000 September 2003Adding Modules to a RailYou can add modules to a rail by in the active island by several different methods (See Ad

Seite 22 - 890USE18000 September 2003

Elements890USE18000 September 2003 29Adding More RailsEach island is graphically displayed as one or more segments on DIN rails. The first segment is

Seite 23

890USE18000 September 2003 3Table of ContentsSafety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5About the Bo

Seite 24 - Workspace Browser

Elements30890USE18000 September 2003Shortcut Menus When you right-click on an item in the island editor, a short menu with a list of commands displays

Seite 25 - 890USE18000 September 2003 25

Elements890USE18000 September 2003 31The Catalog BrowserOverview The catalog browser is a list of all the modules in the Advantys STB product catalog.

Seite 26

Elements32890USE18000 September 2003Here is a top-level view of the catalog browser: Each module type in the catalog browser can be expanded to list t

Seite 27 - 890USE18000 September 2003 27

Elements890USE18000 September 2003 33Adding New Modules to the Catalog BrowserYou will need to add new modules to the catalog browser:when a new relea

Seite 28

Elements34890USE18000 September 2003The Log WindowOverview The log window displays the results of the operations performed by the Advantys configurati

Seite 29

890USE18000 September 2003 353Creating an Island Bus ConfigurationIntroductionOverview This chapter describes how a logical island configuration can b

Seite 30

Creating an Island Configuration36890USE18000 September 2003Creating a WorkspaceOverview Before you can create a.isl file for a logical island, you ne

Seite 31

Creating an Island Configuration890USE18000 September 2003 37The RailsOverview A single empty rail appears in the island editor as soon as a new islan

Seite 32 - Catalog Browser Commands

Creating an Island Configuration38890USE18000 September 2003Adding Modules to an Island SegmentOverview There are three ways to add the modules to a r

Seite 33

Creating an Island Configuration890USE18000 September 2003 39Enter Key MethodThe Enter key method is similar to the double-click method:If you want to

Seite 34 - The Log Window

4 890USE18000 September 2003Chapter 4 Accessing the Software Editors . . . . . . . . . . . . . . . . . . . . . . . . 49Introduction . . . . . . . . .

Seite 35 - Configuration

Creating an Island Configuration40890USE18000 September 2003Adding Extension Rails to the Island ConfigurationProcedure You can extend the island conf

Seite 36 - Creating a Workspace

Creating an Island Configuration890USE18000 September 2003 41Extending the Configuration to a Preferred ModuleProcedure To extend an island configurat

Seite 37 - The Rails

Creating an Island Configuration42890USE18000 September 2003Extending the Configuration to Standard CANopen DevicesProcedure An Advantys STB island do

Seite 38

Creating an Island Configuration890USE18000 September 2003 43Note: There is no graphical element in the software to indicate termination on a standard

Seite 39

Creating an Island Configuration44890USE18000 September 2003Adding and Deleting Annotation to an IslandAdding AnnotationText comments can be placed in

Seite 40

Creating an Island Configuration890USE18000 September 2003 45Retrieving Text for an Annotation BoxTo retrieve text that has just been deleted from an

Seite 41

Creating an Island Configuration46890USE18000 September 2003Offline ProtectionOverview Whenever you open an existing island (.isl) file, it comes up l

Seite 42

Creating an Island Configuration890USE18000 September 2003 47Unlocking After a password has been applied to a .isl file, you need to know the password

Seite 43

Creating an Island Configuration48890USE18000 September 2003Online ProtectionOverview An online protection capability is available to prevent unauthor

Seite 44

890USE18000 September 2003 494Accessing the Software EditorsIntroductionOverview The Advantys configuration software features a set of online and offl

Seite 45

890USE18000 September 2003 5§Safety InformationImportant InformationNOTICE Read these instructions carefully, and look at the equipment to become fami

Seite 46 - Offline Protection

Accessing Editors50890USE18000 September 2003The Module EditorOverview The modular editor provides access to some of the key functions of the Advantys

Seite 47 - 890USE18000 September 2003 47

Accessing Editors890USE18000 September 2003 51Accessing the Module EditorThere are several ways to open the module editor. In all cases, you must firs

Seite 48

Accessing Editors52890USE18000 September 2003Modifying Module Parameters in the Properties TabOverview The Properties tab on the module editor contain

Seite 49 - Introduction

Accessing Editors890USE18000 September 2003 53Numeric Display FormatMany of the parameter values are displayed and can be entered in either decimal or

Seite 50 - The Module Editor

Accessing Editors54890USE18000 September 2003Parameters Table and Configuration GuidelinesThe contents of the parameters table (item 5 above) are diff

Seite 51 - Accessing Editors

Accessing Editors890USE18000 September 2003 55Accessing the Reflex EditorOverview The reflex editor allows you to configure reflex actions in your isl

Seite 52

Accessing Editors56890USE18000 September 2003The Reflex Editor The look of the reflex editor begins to take shape when you select an Action group and

Seite 53

Accessing Editors890USE18000 September 2003 57Accessing the Resource Analysis DisplayOverview Each island in the active workspace has a Resource Analy

Seite 54

Accessing Editors58890USE18000 September 2003The Power Tab The Power tab displays the percentage of logic power and field power consumed by the I/O mo

Seite 55 - Accessing the Reflex Editor

Accessing Editors890USE18000 September 2003 59The Configuration TabThe Configuration tab displays the percentage of:configuration memory consumed in t

Seite 56

Safety Information6890USE18000 September 2003PLEASE NOTE All pertinent state, regional, and local safety regulations must be observed when installing

Seite 57

Accessing Editors60890USE18000 September 2003I/O Image OverviewOverview The I/O Image Overview display provides a summary view of data and status valu

Seite 58

Accessing Editors890USE18000 September 2003 61Fieldbus Image TabEach fieldbus protocol transfers data in a specific format. Often a fieldbus protocol

Seite 59 - 890USE18000 September 2003 59

Accessing Editors62890USE18000 September 2003Modbus Image TabThe Modbus protocol is the format in which data are transferred across the island bus. It

Seite 60 - I/O Image Overview

890USE18000 September 2003 635Verifying an Island ConfigurationIntroductionOverview This chapter describes how to verify that your configuration is va

Seite 61

Verifying an Island Configuration64890USE18000 September 2003Verifying Your Island ConfigurationOverview Before you download your island configuration

Seite 62

Verifying an Island Configuration890USE18000 September 2003 65If one or more standard CANopen devices are used on an island, the last module on the la

Seite 63

Verifying an Island Configuration66890USE18000 September 2003Printing a ReportOverview Ten different types of reports can be printed from the software

Seite 64

Verifying an Island Configuration890USE18000 September 2003 67The following figure is an example of the Print dialog box. Report File FormatsWith the

Seite 65

Verifying an Island Configuration68890USE18000 September 2003

Seite 66 - Printing a Report

890USE18000 September 2003 696Downloading/Uploading Configuration DataIntroductionOverview When the Advantys configuration software is online, you can

Seite 67 - Report File

890USE18000 September 2003 7About the BookAt a GlanceDocument Scope This document provides basic information and instructions for getting the Advantys

Seite 68

Download/Upload Configurations70890USE18000 September 2003Downloading Configuration Data to the Physical IslandOverview When you download a new island

Seite 69

Download/Upload Configurations890USE18000 September 2003 71Uploading Configuration Data to the Advantys Configuration SoftwareOverview You can upload

Seite 70

Download/Upload Configurations72890USE18000 September 2003Uploading to an Existing .isl FileTo upload a configuration to an existing .isl file in the

Seite 71

Download/Upload Configurations890USE18000 September 2003 73Uploading an Auto-configurationAn autoconfiguration is one that has not been configured in

Seite 72 - Existing .isl File

Download/Upload Configurations74890USE18000 September 2003

Seite 73 - 890USE18000 September 2003 73

890USE18000 September 2003 757Using Other Standard CANopen DevicesImporting and Exporting EDS FilesOverview of Importing an EDS FileTo use a standard

Seite 74

Standard CANopen Devices76890USE18000 September 2003Exporting an EDS FileIf the fieldbus on which your island will operate uses EDS files to define th

Seite 75 - Using Other Standard CANopen

890USE18000 September 2003 77Glossary10Base-T An adaptation of the IEEE 802.3 (Ethernet) standard, the 10Base-T standard uses twisted-pair wiring with

Seite 76

Glossary78890USE18000 September 2003ARP address resolution protocol. IP’s network layer protocol uses ARP to map an IP address to a MAC (hardware) add

Seite 77

Glossary890USE18000 September 2003 79CiA CAN in Automation. CiA is a non-profit group of manufacturers and users dedicated to developing and supportin

Seite 78 - Glossary

About the Book8890USE18000 September 2003Product Related WarningsSchneider Electric assumes no responsibility for any errors that may appear in this d

Seite 79

Glossary80890USE18000 September 2003EDS electronic data sheet. The EDS is a standardized ASCII file that contains information about a network device’s

Seite 80

Glossary890USE18000 September 2003 81Fipio Fieldbus Interface Protocol (FIP). An open fieldbus standard and protocol that conforms to the FIP/World FI

Seite 81

Glossary82890USE18000 September 2003HMI human-machine interface An operator interface, usually graphical, for industrial equipment.HMI human-machine i

Seite 82

Glossary890USE18000 September 2003 83IEC type 1+ input Type 1+ digital inputs support sensor signals from mechanical switching devices such as relay c

Seite 83

Glossary84890USE18000 September 2003LAN local area network. A short-distance data communications network.light industrial I/OAn Advantys STB I/O modul

Seite 84

Glossary890USE18000 September 2003 85N.C. contact normally closed contact. A relay contact pair that is closed when the relay coil is de-energized and

Seite 85

Glossary86890USE18000 September 2003output polarity An output channel’s polarity determines when the output module turns its field actuator on and whe

Seite 86

Glossary890USE18000 September 2003 87preferred module An I/O module that functions as an auto-addressable node on an Advantys STB island but is not in

Seite 87

Glossary88890USE18000 September 2003repeater An interconnection device that extends the permissible length of a bus.reverse polarity protectionUse of

Seite 88

Glossary890USE18000 September 2003 89SELV safety extra low voltage. A secondary circuit designed and protected so that the voltage between any two acc

Seite 89

890USE18000 September 2003 91Hardware and Software RequirementsIntroductionOverview The Advantys configuration software is designed to run on various

Seite 90

Glossary90890USE18000 September 2003standard network interfaceAn Advantys STB network interface module designed at moderate cost to support the kind o

Seite 91

Glossary890USE18000 September 2003 91UDP user datagram protocol. A connectionless mode protocol in which messages are delivered in a datagram to a des

Seite 92

Glossary92890USE18000 September 2003

Seite 93 - 890USE18000 September 2003 93

CBA890USE18000 September 2003 93Aaccessories, 31adding annotation, 44adding modules, 38adding rails to the configuration, 40analog input modules, 31an

Seite 94

Index94890USE18000 September 2003Llocking an island file, 46logical island, 15Mmodule typeslisted in the catalog browser, 31modulesadding, 38moving a