GLOSSARY
TERMS
accumulated energy—energy can accumulates in either signed or
unsigned (absolute) mode. In signed mode, the direction of power flow is
considered and the accumulated energy magnitude may increase and
decrease. In absolute mode, energy accumulates as a positive regardless
of the power flow direction.
active alarm—an alarm that has been set up to trigger the execution of a
task or notification when certain conditions are met. An icon in the upper-
right corner of the meter indicates that an alarm is active (!). See also
enabled alarm and disabled alarm.
baud rate—specifies how fast data is transmitted across a network port.
block interval demand—power demand calculation method for a block of
time and includes three ways to apply calculating to that block of time
using the sliding block, fixed block, or rolling block method.
communications link—a chain of devices connected by a
communications cable to a communications port.
current transformer (CT)—current transformer for current inputs.
demand—average value of a quantity, such as power, over a specified
interval of time.
device address—defines where the power meter resides in the power
monitoring system.
event—the occurrence of an alarm condition, such as Undervoltage
Phase A, configured in the power meter.
firmware—operating system within the power meter
fixed block—an interval selected from 1 to 60 minutes (in 1-minute
increments). The power meter calculates and updates the demand at the
end of each interval.
float—a 32-bit floating point value returned by a register. The upper 16-
bits are in the lowest-numbered register pair. For example, in the register
4010/11, 4010 contains the upper 16-bits while 4011 contains the lower
16-bits.
frequency—number of cycles in one second.
line-to-line voltages—measurement of the rms line-to-line voltages of the
circuit.
line-to-neutral voltages—measurement of the rms line-to-neutral
voltages of the circuit.
maximum demand current—highest demand current measured in
amperes since the last reset of demand.
maximum demand real power—highest demand real power measured
since the last reset of demand.
maximum demand voltage—highest demand voltage measured since
the last reset of demand.
maximum demand—highest demand measured since the last reset of
demand.
maximum value—highest value recorded of the instantaneous quantity
such as Phase A Current, Phase A Voltage, etc., since the last reset of the
minimums and maximums.