Instruction Bulletin
S1B35793
Rev. 01, 08/2011
Replaces S1B35793, 07/2011
Wiser™ Thermostat Remote Temperature Sensor
Model EER57200
Retain for future use.
© 2011 Schneider Electric All Rights Reserved
ENGLISH
Description The EER57200 is a surface mount temperature sensor for use with Wiser
Programmable Communicating Thermostats, models EER56000 and
EER56100. The sensor can be:
Connected to a Wiser thermostat to monitor the temperature of a remote
location
Combined with an onboard temperature sensor to average the
temperature of two locations
Used to monitor the outdoor temperature
The remote temperature sensor is required for Wiser thermostats used in dual
fuel heat pump installations.
Safety Precautions This section contains important safety precautions that must be followed before
attempting to install, maintain, or troubleshoot electrical equipment. Carefully
read and follow the safety precautions below.
Installation 1. Install the thermostat base and connect it to the HVAC equipment.
Consult the HVAC manufacturer’s instructions and the thermostat
Installer’s Guide.
2. Connect the thermostat to the base and confirm that the thermostat
operates correctly.
3. Disconnect the thermostat from the base.
4. Run a twisted pair, shielded cable from the remote thermostat to the
mounting location of the temperature sensor. Follow these guidelines or
product performance may be degraded:
Wire runs must not exceed 250 feet.
For distances up to 100 feet, typical twisted pair, PVC-insulated
shielded cable must be used.
For distances from 100–150 feet, twisted pair shielded cable with
polypropylene insulated conductors must be used.
For distances from 150–250 feet, twisted pair shielded cable with
foam-polyethylene insulated conductors must be used.
DANGER
HAZARD OF ELECTRIC SHOCK
Apply appropriate personal protective equipment (PPE) and follow safe
electrical work practices. See NFPA 70E.
This equipment must be installed and serviced by qualified electrical
personnel.
Turn off all electrical power supplying this equipment before working on
or inside the equipment.
Always use a properly rated voltage sensing device to confirm that
power is off.
Replace all devices, doors, and covers before turning on power to this
equipment.
Failure to follow these instructions will result in death or serious
injury.
Seitenansicht 0
1 2 3 4 5 6

Inhaltsverzeichnis

Seite 1 - Instruction Bulletin

™Instruction BulletinS1B35793Rev. 01, 08/2011Replaces S1B35793, 07/2011Wiser™ Thermostat Remote Temperature SensorModel EER57200 Retain for future use

Seite 2 - Temp. Sensor

WiserTM Thermostat Remote Temperature Sensor S1B35793Instruction Bulletin Rev. 01, 08/2011Electrical equipment should be installed, operated, service

Seite 3 - Boletín de instrucciones

™Boletín de instruccionesS1B35793Rev. 01, 08/2011Reemplaza S1B35793, 07/2011Sensor de temperatura remoto del termostato Wiser™Modelo EER57200 Conserva

Seite 4 - Sensor de temperatura

Sensor de temperatura remoto del termostato Wiser™ S1B35793Boletín de instrucciones Rev. 01, 08/2011Solamente el personal especializado deberá instal

Seite 5 - Directives d’utilisation

™Directives d’utilisationS1B35793Rév. 01, 08/2011Remplace S1B35793, 07/2011Capteur de température à distance du thermostat WiserMCModèle EER57200 À co

Seite 6 - FRANÇAIS

Capteur de température à distance du thermostat WiserMC S1B35793Directives d’utilisation Rév. 01, 08/2011Seul un personnel qualifié doit effectuer l’i

Kommentare zu diesen Handbüchern

Keine Kommentare